II.C Installing Faucet with Capacity Monitor
(continued)
Installation of the Electronics Box
1. Attach the two adapters (item # 9) to the Electronics box -- one on each side.
2. Guide the red & black wires (# 6) from under the sink to the Electronics Box and snap the plug
onto the plug coming from the Electronics Box.
3. Open the Electronics Box and insert two AAA batteries (not included), matching polarity shown on
the battery holder. There will be a long audio sound, and the LED will flash red and green several
times before finally flashing green.
4. Snap the cover back onto the Electronics Box.
5. After you connect the tubing (see below), then peel off the paper backing from the Velcro®
and attach one piece to the back of the Electronics Box and the second piece to a clean,
convenient location of the cabinet wall under the sink and press the Box onto the wall.
Connecting the Tubing
(See Section IV.B for tips on connecting tubing)
Faucet Connection:
Connect the tubing attached to the faucet to the adapter on the left side of the Capacity
Monitor.
1. Using wire cutters or knife, cut (square cut) the tip end off of the plastic tube
connected to the faucet. Do not use scissors.
2. The tubing must be fully inserted in the adapter. It is recommended that you measure
and mark the end of the tubing that you are inserting in the adapter to assure that it is
inserted as far as it will go. The 1/4” tubing should be inserted about 5/8”.
3. Push the tubing through the small hole in the adapter until you feel resistance; at
this point, the tubing is not fully inserted. Then push firmly until the tubing is
inserted as far as it will go (see Item 2 above for measurement).
Housing Connection:
When you have completed the installation of your drinking water system below your sink,
then connect the separate piece of tubing (#11) to the Small Straight Adapter that you pre-
viously attached to the OUTLET port of the housing and then to the adapter on the right
side of the Capacity Monitor.
1. Using wire cutters or knife, cut (square cut) the tip end off of the plastic tube
connected to the faucet. Do not use scissors.
2. The tubing must be fully inserted in the adapter. It is recommended that you measure
and mark the end of the tubing that you are inserting in the adapter to assure that it is
inserted as far as it will go. The 1/4” tubing should be inserted about 5/8”.
3. Push the tubing through the small hole in the adapter until you feel resistance; at
this point, the tubing is not fully inserted. Then push firmly until the tubing is inserted
as far as it will go (see Item b above for measurement).
To Indicator
To Electronics
Box
Plug
Plug
Insert tubing and push until you
feel resistance -- at this point,
the tubing is not fully inserted.
Push firmly until the tubing is
inserted as far as it will go.
blue tubing
OUTLET
Adapter
Pull to check that the
tubing is secure.
insert
insert
Operation and Maintenance of Models with Capacity Monitor:
Multi-Pure Drinking Water Systems that are equipped with a capacity monitor lets you know when the
filter should be changed. When you turn on your Multi-Pure drinking water faucet, and water flows
through the capacity monitor, the green light on the capacity indicator plate flashes several times to let
you know that the System has not reached its certified capacity. The number of green flashes will
decrease as the capacity of your monitor is used. When it flashes just two times, only 20% of your
capacity remains; one time indicates only 10% of the capacity remains. It is recommended that you
order a replacement filter when you reach the 20% capacity level.
A red light will flash alerting you that the capacity of your filter has been fully used and that you should
immediately replace the filter. You also will hear an audio alert.
As with all drinking water treatment devices which reduce certain contaminants by mechanical filtration, the capacity of the
filter will vary and is dependent upon type and level of contaminants in your water. It is recommended that a prefilter be
installed in front of models with a capacity monitor when used on water with high levels of particulate matter.
It is recommended that you replace the filter cartridge when the first of the following occurs: a) annually; b) the red light
flashes on the capacity indicator plate, indicating that the unit's rated capacity has been reached; c) the flow rate dimin-
ishes; or d) the filter becomes saturated with bad tastes and odors.