If your residence has a cold water supply line with a 3/8" slip joint connection, you may
use the Extender Tee Adapter (optional) to connect your Drinking Water System to the
plumbing. Drinking Water Systems shipped with an Extender Tee Adapter include:
- Shut-off Valve with adapter (#11) - MC1875
- 3/8" Extender Tee Adapter Assembly (#13) - MC120 or (#14) MC165 (
PR tee)
which includes: 3/8" Compression Nut, Delrin Sleeve, Brass Insert
(for corresponding numbers, see diagram on page 4)
1. Install on the cold water line only.
2. Shut off your water at the cold water supply line - angle stop valve under your sink. You
should have on hand a container to catch any residual water in the pipes.
3. Disconnect the cold water riser/supply line at the angle stop valve by turning counter
clockwise the slip joint nut, using an 8" adjustable wrench.
4. Using the 8" adjustable wrench, connect the 3/8" Extender Tee Adapter to your angle
stop valve. Turn clockwise until tight; however, DO NOT OVERTIGHTEN.
5. Reconnect the cold water riser/supply line with the slip joint nut to the Extender Tee
Adapter. Turn clockwise until tight.
6. Connect the clear plastic tubing to the Extender Tee, as follows:
a. Insert the clear plastic tubing shipped with the unit through the small hole in the
3/8" compression nut (first unscrew the nut from the tee and remove the brass
sleeve - if found).
b. Insert the brass insert into the end of the plastic tubing.
c. Slide the plastic delrin sleeve, included with the assembly hardware, large end
first over the plastic tubing and insert into the compression nut (the brass
sleeve, if found, in the compression nut may be discarded).
d. Connect the 3/8" compression nut, with tubing attached, to the Extender Tee
Adapter by inserting tubing in the hole on the side of the extender tee adapter
as far as it will go. Tighten the compression nut by hand and then give one to
two extra turns with a wrench. Tighten securely, making sure the tubing does
not pull out, but DO NOT OVERTIGHTEN.
7. To connect the clear plastic tubing to your drinking water unit proceed to Section V.
NOTE: The shut-off valve will be connected to the inlet port on the unit top. See Section V
for instructions.
Water supply line
before installation.
sink
riser
cold
slip joint nut
Water supply line with
extender tee installed
12
III.C Extender Tee Adapter Installation
angle stop valve
angle stop
valve
extender tee
cold
riser
slip joint
nut
clear
tubing
to unit
clear plastic
tubing to unit
3/8”compression nut
brass insert
plumbing angle
stop valve
Extender Tee
Adapter
Connect to slip joint nut and cold
water supply line.
plastic delrin
sleeve